          • (H) GW9-12 Outdoor High Voltage Ac Disconnector

          (H) GW9-12 Outdoor High Voltage Ac Disconnector

          (H) GW9-12 series outdoor high-voltage AC single-phase isolating switch (hereinafter referred to as "isolation switch"), for 10kV line to be exchanged under voltage and no load, as well as for high-voltage busbars, circuit breakers and other electrical equipment to be repaired Electrically isolated from live high voltage lines. The isolating switch complies with GB 1985-2014 "High Voltage AC Isolation Switch and Grounding Switch", DL/T486-2010 (High Voltage AC Isolation Switch and Grounding Switch) and other technical standards.

          Technical Information

          Technical Specification

           

           

           

          Rated frequency

           

          Hz

          50

          Rated voltage

           

          kV

          12

          Rated current

           

          A

          630(250)

          Rated short-time withstand current and duration

          kA/s

          20(25)/4

          Rated peak withstand current

          kA

          50(63)

          Rated short-time power frequency withstand voltage

           

          Interphase and ground (dry test)

          kV/min

          42/1

           

          Fracture (dry test)

          kV/min

          48/1

           

          Phase to ground (wet test)

          kV/min

          30/1

           

          Fracture (wet test)

          kV/min

          36/1

           

          Lightning impulse withstand voltage

           

          Phase to ground

          kV

          75

           

          Fracture

          kV

          85

          Loop resistance

           

          μΩ

          ≤80

          Mechanical life

           

          Times

          3000

          Pollution level

           

           

          e Class

          Creepage distance

           

          mm

          ≥372