1. <wbr id="54aby"><source id="54aby"><option id="54aby"></option></source></wbr>
      <wbr id="54aby"></wbr>
        <nav id="54aby"></nav>

        <form id="54aby"></form>
      1. Hello! welcomeZhejiang Xikai Electric Co. , Ltd.
        Zhejiang Xikai Electric Co. , Ltd.
        Contact
        Zhejiang Xikai Electric Co. , Ltd.
        Mailbox:wzxikai@wzxikai.com
        Tel:+86 577 61666 016
        address:No.271, Weishiqi Road, Yueqing Economic Development Insuatrial Zone, Yueqing, Zhejiang.

        product list

        Indoor high voltage load switch
        14/5000 Indoor vacuum circuit breaker
        Outdoor vacuum circuit breaker
        Outdoor high voltage load switch
        Outdoor high voltage disconnector
        Outdoor drop fuse
        High voltage current limiting fuse series
        High voltage complete set
        current position:Home>Product Center

        Product Center

          • GW1-12 Outdoor High Voltage Ac Disconnector

          GW1-12 Outdoor High Voltage Ac Disconnector

          GW1-12 series outdoor high-voltage AC isolating switch (hereinafter referred to as “isolation switch”), suitable for installation on outdoor high-voltage power distribution equipment line, for 10kV line to be connected under voltage and no load, and for high voltage to be overhauled Electrical equipment such as busbars and circuit breakers can be electrically isolated from live high-voltage lines, and can also be used to separate small capacitive currents and inductor currents. The isolating switch is a double-column vertical open type with manual or electric mechanism for three-phase linkage. The isolating switch complies with GB 1985-2014 "High Voltage AC Isolation Switch and Grounding Switch", DL/T 486-2010 "High Voltage AC Isolation Switch and Grounding Switch" and other technical standards.

          Technical Information

          Technical Specification

           

           

           

           

           

           

           

           

           

           

           

          Rated voltage

           

          kV

           

           

           

          12

           

           

          24

          40.5

          Rated frequency

           

          Hz

           

           

           

           

           

          50

           

           

          Rated current

           

          A

           

          630

           

          1250(1600)

          630

          Rated short-time withstand current and duration

          Isolation switch

          kA/s

          20/4

           

          25/4

           

          25/4

           

          31.5/4

          20/4

          25/4

          Grounding switch

          kA/s

          20/2

           

          25/2

           

          25/2

           

          31.5/2

          20/2

          25/2

          Rated peak withstand current

          kA

          25

           

          63

           

          63

           

          80

          25

          63

          Rated short-time power frequency withstand voltage

          Interphase and ground (dry test)

          kV/min

           

           

           

          42/1

           

           

          50

          95

          Fracture (dry test)

          kV/min

           

           

           

          48/1

           

           

          60

          115

          Phase to ground (wet test)

          kV/min

           

           

           

          42/1

           

           

          50

          85

          Lightning impulse withstand voltage

          Phase to ground

          kV

           

           

           

          75

           

           

          125

          185

          Fracture

          kV

           

           

           

          85

           

           

          145

          215

          Loop resistance

           

          μΩ

          ≤100

           

          ≤80

          ≤90

          ≤100

               

           

          Mechanical life  
          Times
          Isolation switch / grounding switch 